Engineering Dashboard

Live compliance & session integrity
READY
--
Session Integrity
No data
Run a module
Active Modules
0
calculators run
Audit Records
0
signed & chained
Device Key
ECDSA P-256
Live Compliance

Module Status

    Trace

    Recent Events

    No events yet.
    ⚠ Professional Use & Verification

    Outputs are indicative engineering estimates for preliminary screening, not certified designs, approved permits, or a substitute for the governing standard edition and qualified-engineer review. Verify all safety-critical results before field use.

    Module 01

    Pressure-Test Exclusion Zone

    METHOD · STORED-ENERGY / TNT-EQUIVALENT SCREENING · API 521 / ASME PCC-2 GUIDANCE
    Conservative compressed-gas exclusion-distance screening for pneumatic / nitrogen testing.
    Results
    Enter parameters and press Calculate.
    Module 02

    Structural & Rigging Suite

    STANDARD · ASME B30 / AISC 360 METHODS
    From sling tag (already includes design factor).
    Results
    Enter parameters and press Calculate.
    From geotech report.
    Results
    Enter parameters and press Calculate.
    Results
    Pick a section or enter I/S, then Check.
    Results · AISC E3
    Enter parameters and Calculate.

    Fillet Weld (shear)

    Combined Axial + Bending (AISC H1)

    Weld / Interaction Results
    Run a check above.
    Module 03

    Hazard & Fire Safety

    STANDARD · NFPA / API RP 2218 / OSHA METHODS
    Lumped-capacitance unprotected-steel heating (ISO 834) and indicative protection thickness. Use tested PFP product data for final thickness.
    Results
    Enter parameters and Calculate.
    Generates isolation sequence and tagout checklist from energy sources present.
    Isolation Procedure
    Select sources and generate.
    Classifies entry conditions against OSHA 1910.146 atmospheric thresholds. Continuous monitoring is always required.
    Classification
    Enter readings and classify.
    Module 04

    Advanced Field Safety

    OSHA 1926 / ASME B30 / NFPA 51B WORKFLOWS
    Lift Classification
    Enter details and classify.
    OSHA 1926 Subpart P sloping/benching screening.
    Assessment
    Enter details and assess.
    Duty-rating and base-bearing screening (OSHA 1926 Subpart L).
    Verification
    Enter details and verify.
    NFPA 51B hot work permit checklist generator.
    Hot Work Permit
    Enter details and generate.
    Rule-based PPE recommendation from selected hazards.
    PPE Recommendation
    Select hazards and recommend.
    Module 05

    Advanced Structural

    AISC 360 / ASME BTH-1 METHODS · SCREENING-GRADE
    0 = capacity only.
    Results · AISC F2
    Enter parameters and Calculate.
    Results · AISC B4.1
    Enter b/t and h/tw, then Classify.
    Results
    Enter group geometry and Calculate.
    Results
    Enter plate & column data, then Calculate.
    Results · AISC J3
    Enter bolt data and Calculate.
    Results · Padeye
    Enter lug geometry and Calculate.
    Results · Spreader
    Enter geometry and Calculate.
    Module 06

    Engineering Drawings & DXF Export

    SVG ON SCREEN · CAD-OPENABLE DXF (AC1009 / R12)
    Generates schematic sketches from your current inputs and exports them as DXF for CAD or SVG for documents. Diagrams are schematic and not to scale.
    Loading drawing...
    Reporting Engine

    Reports, Certificates & QR

    PDF / XLSX / QR · AIENGINEAR BRANDED · AUDIT-LINKED
    Generate a branded certificate from any saved audit record. The QR encodes the record UUID, hash prefix, type, timestamp and a verification checksum.
    Workflow

    Permit-to-Work Register

    DRAFT → SUBMITTED → APPROVED → CLOSED · PERSISTED LOCALLY
    IDTypeTitleStatusAction
    Integrity & Compliance

    Tamper-Evident Audit Log

    SHA-256 HASH CHAIN · ECDSA P-256 SIGNATURES · UUID CERTIFICATE IDS
    Append-only, hash-chained and digitally signed with a device key. Verify recomputes every hash, checks the chain links and timestamp ordering, and validates each signature.
    SafeSite Construct™ Ultimate v9.0

    About this suite

    A fully offline, client-side field-safety and construction engineering suite by AIEnginear.com. No server, no CDN, no telemetry. All data and audit records persist in your browser's IndexedDB on this device.
    • 01Pressure-test exclusion — stored-energy / TNT-equivalent screening (API 521 / ASME PCC-2 guidance).
    • 02Rigging & structural — sling tension (ASME B30), crane ground bearing, beam check & auto-selection, column buckling & slenderness (AISC E3), fillet weld, combined-stress interaction (AISC H1).
    • 03Hazard & fire — section-factor fireproofing, LOTO builder, confined-space classification (NFPA / API RP 2218 / OSHA).
    • 04Field safety — critical-lift planner, excavation (Subpart P), scaffolding (Subpart L), hot-work permit (NFPA 51B), PPE engine.
    • 05Enterprise audit — SHA-256 chain + ECDSA P-256 signatures + UUID IDs, tamper detection, QR/PDF/XLSX reporting.
    ⚠ Professional Use, Limitations & Verification

    SafeSite Construct™ is an engineering decision-support and documentation aid for qualified professionals. All outputs are indicative and intended for preliminary screening only. They do not constitute a certified design, an approved permit, or a substitute for the governing edition of each standard, site-specific analysis, or the judgement of a competent person. The pressure-test exclusion method is a simplified energy-scaling screen, not the full API 521 / ASME PCC-2 procedure or a site blast study. Section-library values are nominal and must be confirmed against published section tables. Verify and approve all safety-critical results within your organisation's safety management and permit-to-work systems before any field use. No warranty is expressed or implied.

    Saved