Summary based on ISO 5167-2 Table 3 (values in pipe diameters D, upstream length measured from the upstream face of the plate). For a β between rows the value of the next higher β row is used. ISO 5167-2:2022 corrected the two-45°-bend spacing and clarified the tee configuration; always confirm against your licensed copy, and consider a flow conditioner (Annex C) where space is short.
Use this table to configure square-root extraction in the transmitter or DCS. Readings below about 10 % of DP span (about 32 % of flow) carry much larger uncertainty; consider stacked transmitters or a smart wide-range transmitter for high turndown.
Hydraulic power lost = actual volume flow × permanent pressure loss ÷ efficiency. For a compressible fluid this is a screening estimate based on upstream density.
Expected values were derived independently of this page (separate reference implementation of ISO 5167-2 equations, unit definitions from NIST SP 811 and ASME B36.10M dimensions). The badge in the header turns green only when every test passes.