What are the types of olets?

An olet is a forged, integrally reinforced branch outlet fitting welded onto a run pipe (header) over a hole, so a smaller branch can leave the header without a tee or a reinforcing pad. The types of olets differ in two ways. By branch end: butt-weld (weldolet), socket-weld (sockolet) or female thread (thredolet). By geometry: on an elbow (elbolet), at 45° (latrolet), with an integral nipple (nipolet), as a light threaded fire-service outlet (coupolet) or with a contoured, butt-welded saddle (sweepolet). Standard 90° and 45° forged outlets are made to MSS SP-97-2025 and installed under ASME B31.3 or ASME B31.1.

Product standardMSS SP-97-202590° and 45° outlets, BW / SW / THD
Process codeASME B31.3-2024§304.3 branch connections
Power codeASME B31.1-2026issued September 2026
Install guidePFI ES-49-2023hole size, fit-up, weld profile
Hole ruleCut = olet borenever the branch OD
Attachment weldFull penetrationgroove weld + cover fillet

Open the olet calculatorJump to comparison table

What is an olet?

Whenever a smaller line — a drain, vent, instrument tap, sample point or process branch — has to leave a larger pipe, the hole cut in the larger pipe weakens its wall. That lost strength has to be put back somewhere. An olet puts it back with extra metal forged into the fitting itself. The olet sits on the outside of the run pipe, its base is contoured to the pipe’s curvature, and it is joined to the run with a full-penetration groove weld. The branch pipe, valve or instrument then connects to the top of the olet.

“Olet” is the shop-floor and piping-specification shorthand. Names such as Weldolet®, Sockolet®, Thredolet®, Elbolet®, Latrolet®, Nipolet® and Sweepolet® are registered trademarks of Bonney Forge, the company that developed and popularised the design. Standards use the neutral term integrally reinforced forged branch outlet fittings, and many forges make equivalent products under their own names — so a requisition should describe the fitting by standard, end type, sizes and material, not by brand alone.

How an olet reinforces a branch

Piping codes handle a branch opening with area replacement: metal removed to make the hole must be balanced by surplus metal close to the opening. For a fabricated branch the designer proves this by calculation and often adds a reinforcing pad. For an olet, the reinforcement is already in the forged body — the thick, tapered shoulder around the bore.

MSS SP-97 states the design intent: a fitting made to the standard gives a fully reinforced branch connection when it is attached over an opening in the run pipe with a full-penetration weld. Two conditions follow, and both are often missed on site:

  • The wall pairing must match. Unless the manufacturer states otherwise, conventional SP-97 outlets are intended for the header × branch combinations in Table 1. For mixed schedules — for example an XS outlet on a Sch 10S header — the manufacturer must confirm the selection.
  • The attachment weld is part of the reinforcement. A partial-penetration or fillet-only attachment does not deliver the strength the fitting was designed for. ASME B31.3 §328.5.4 requires branch connection fittings that abut the run to be attached with fully penetrated groove welds.
AIENGINEARTable 1. Standard header × branch wall pairings for SP-97 outlets
Header (run) wallMatching outletBranch endTypical opening ≈ bore of
STDSTD outletButt-weldSTD branch pipe ID
XSXS outletButt-weldXS branch pipe ID
Sch 160Sch 160 outletButt-weldSch 160 branch pipe ID
XXSXXS outletButt-weldXXS branch pipe ID
XSClass 3000Socket-weld or threadedXS branch pipe ID
Sch 160Class 6000Socket-weld or threadedSch 160 branch pipe ID
XXSClass 9000Socket-weldXXS branch pipe ID
Any other mixManufacturer selection—Per certified drawing

Pairings per MSS SP-97-2025 scope notes; bore column is typical practice — the manufacturer’s certified drawing governs. Compiled by Aienginear — aienginear.com/types-of-olets/

Under ASME B31.3 §304.3.2, branch connections made with listed fittings such as MSS SP-97 outlets are accepted without a separate area-replacement calculation, provided they are used within the standard’s scope. Fittings outside a listed standard are unlisted components and need their pressure design qualified under §304.7.2.

Olet vs tee vs fabricated branch

Branch connection methods comparedOriginal schematic comparing three ways to make a branch: a fabricated stub-in with reinforcing pad, a butt-welding tee, and an integrally reinforced olet. Three ways to take a branch off a run pipeA Fabricated branch + padCalc per B31.3 §304.3.3; padadds welds and a vent holepad welds + branch weldB Butt-welding tee (B16.9)Listed fitting; run must be cutand re-welded; most weld volume3 butt welds (2 run + 1 branch)C Olet (MSS SP-97)Listed fitting; one attachmentweld; no pad needed1 attachment weld + 1 branchAienginear.com
Figure 1 — Three common ways to take a branch: fabricated stub-in with a reinforcing pad, a butt-welding tee, and an olet. Original Aienginear schematic, not to scale.

No single method is best everywhere. Most owners’ piping classes include a branch connection table that tells the designer which method to use for each header and branch size pair — and that table governs. Table 2 explains the reasoning behind it. For tee sizes, see our pipe tee dimensions chart.

AIENGINEARTable 2. Branch connection methods compared
MethodTypically used forAdvantagesLimitations
Butt-welding tee (ASME B16.9)Equal and near-equal branches; high-integrity linesSmooth flow; listed fitting; every weld is a butt weld that can be radiographed or UT-testedRun must be cut and re-welded (3 butt welds); needs spool length; not every reducing ratio is made
Olet (MSS SP-97)Branches clearly smaller than the run — commonly up to about half the run size; small-bore vents, drains and instrument tapsRun stays continuous; no pad; one attachment weld; easy to add to existing linesAttachment weld is hard to examine volumetrically; higher stress intensification than a tee; needs correct hole and fit-up
Fabricated branch (stub-in / stub-on), with or without padLarge, low-pressure branches; non-critical utilities where the class permitsLow material cost; no special fittingsReinforcement calc per B31.3 §304.3.3; extra welding; pads trap moisture and need a vent hole; poor fatigue performance
Half coupling (ASME B16.11)Small-bore taps where the class allowsCheap and widely stockedB31.3 §304.3.2(c): branch ≤ DN 50 (NPS 2) and ≤ ¼ of run size; coupling rating not less than Class 3000
Sweepolet or extruded outletHigh-pressure, cyclic or fatigue-sensitive headersLow stress intensification; attachment weld can be radiographedHigher cost and longer lead time; size range limited per manufacturer

Based on ASME B31.3-2024 §304.3 and common owner piping-class practice. Compiled by Aienginear — aienginear.com/types-of-olets/

Standards and codes for olets (status: November 2026)

Always use the edition named in the contract or required by the jurisdiction. The editions in Table 3 were the latest published when this guide was reviewed on 23 November 2026.

AIENGINEARTable 3. Standards that apply to olets — current editions
DocumentCurrent editionWhat it controls
MSS SP-972025 (published March 2025, replaces 2019)Dimensions, finish, tolerances, testing, marking, materials and minimum strength of 90° and 45° integrally reinforced forged branch outlets with butt-welding, socket-welding and threaded ends
ASME B31.3 — Process Piping2024 (still current; next edition expected)Branch design (§304.3), unlisted components (§304.7.2), socket and threaded joints (§311.2.4, §314), branch welds (§328.5.4), preheat and heat treatment (§330–331), examination (§341), leak testing (§345)
ASME B31.1 — Power Piping2026 (issued September 2026, replaces 2024)Equivalent rules for boiler external piping and power plant piping
ASME BPVC Section VIII, Div. 12025Opening and nozzle reinforcement when an outlet is attached to a vessel shell or head — vessel rules then apply, not piping rules
ASME B16.112021 (revision in progress)Socket and thread dimensions and pressure classes (3000, 6000, 9000) that SW and threaded outlets follow
ASME B16.25Current editionWeld-end bevel preparation for the butt-welding branch end
ASME B1.20.1Current editionNPT taper pipe threads on thredolets, coupolets and threaded nipolets
PFI ES-492023Guidance on hole size, fit-up, weld size and weld profile for integrally reinforced branch fittings
Material specificationsLatest ASTM yearASTM A105/A105N (carbon steel), A350 LF2 (low-temperature CS), A182 F11/F22/F91 (Cr-Mo), A182 F304L/F316L (stainless), B564 (nickel alloys)

Editions checked against MSS, ASME and PFI publication records, 23 November 2026. The contract edition governs. Compiled by Aienginear — aienginear.com/types-of-olets/

Engineer’s note: MSS SP-97 covers 90° and 45° outlets only. Elbolets, sweepolets, insert-type outlets and other special shapes are normally made to the manufacturer’s own design. Before using them in code piping, ask for the design basis (proof test, finite element analysis or calculation) and confirm it satisfies B31.3 §304.7.2 or the B31.1 equivalent. Official sources: MSS, ASME B31.1, PFI.

Types of olets explained

Each of the eight types of olets below has an original section drawing, where it is used, and the points that cause trouble in practice.

1. Weldolet (butt-weld outlet)

90°Butt-weld branchMSS SP-97

Weldolet sectionOriginal schematic section of a weldolet: a forged integrally reinforced outlet set on a run pipe, joined by a full-penetration groove weld, with a butt-welded branch pipe. Weldolet — butt-weld (BW) branch outletRUN PIPE (HEADER) ℄FLOWButt weld to branch pipebevel per ASME B16.25Forged olet bodyintegral reinforcementFull-penetration groove weld+ cover fillet (B31.3 §328.5.4)Opening cut tomatch olet boreBranch pipeAienginear.com
Figure 2 — Weldolet in section: forged body, full-penetration attachment weld and butt-welded branch.

The weldolet is the workhorse of the family. Its top end is bevelled so the branch pipe is joined with an ordinary butt weld. It is matched to the branch pipe wall (STD, XS, Sch 160 or XXS), and one fitting is usually designed to suit a range of header sizes, which simplifies stocking. Reducing sizes are standard; full-size outlets exist, but at that ratio a tee is usually the better choice.

Use it when

  • The branch is NPS 2 (DN 50) or larger, or the class calls for butt welds
  • The line carries hydrocarbons, steam, toxic or high-pressure fluid
  • A tie-in is needed on an existing header without cutting it apart

Watch out for

  • Branch bevel and wall must match the branch pipe schedule
  • Header hole must equal the outlet bore — never the branch OD
  • The root inside the header cannot be seen; rely on a qualified procedure and good fit-up

2. Sockolet (socket-weld outlet)

90°Socket-weld branchClass 3000 / 6000 / 9000

Sockolet sectionOriginal schematic section of a sockolet with a socket-weld branch end, showing the pipe inserted into the socket, the expansion gap and the fillet weld. Sockolet — socket-weld (SW) branch outletRUN PIPE (HEADER) ℄FLOWFillet weld (socket weld)Expansion gap before welding≈1.5 mm (1/16 in) typicalClass 3000 / 6000 / 9000socket per B16.11 dimensionsPipe insertedinto socketGroove weld to runAienginear.com
Figure 3 — Sockolet: the branch pipe slides into a socket and is fillet welded; an expansion gap is left at the bottom.

A sockolet has the same reinforced body as a weldolet, but its top is machined into a socket. The branch pipe is inserted, pulled back to leave a small gap (about 1.5 mm / 1/16 in before welding) and fillet welded. Socket dimensions follow ASME B16.11 practice, and the outlet is ordered by pressure class: 3000 for an XS branch, 6000 for Sch 160 and 9000 for XXS.

Use it when

  • Small-bore branches, usually NPS 2 (DN 50) and below
  • Vents, drains, pressure and temperature tappings, small utility branches
  • Butt-weld fit-up would be awkward at small sizes

Watch out for

  • The crevice between pipe and socket — B31.3 §311.2.4 says to avoid socket welds where crevice corrosion or severe erosion can occur
  • Not suited to severe cyclic or high-vibration service
  • Bottoming the pipe with no gap can crack the weld under thermal cycling

3. Thredolet (threaded outlet)

90°Female NPT branchClass 3000 / 6000

Thredolet sectionOriginal schematic section of a thredolet with an internal tapered pipe thread and a threaded nipple engaged. Thredolet — threaded (NPT) branch outletRUN PIPE (HEADER) ℄FLOWInternal tapered threadNPT per ASME B1.20.1Class 3000 / 6000forged bodyThreaded nippleor plugGroove weld to runAienginear.com
Figure 4 — Thredolet: an internal taper pipe thread receives a nipple, plug, thermowell or instrument fitting.

A thredolet is welded to the header like any other olet, but its branch end carries an internal taper pipe thread — normally NPT to ASME B1.20.1. An instrument, plug or threaded valve can then be fitted and removed without hot work, which is why thredolets are common on instrument and utility connections.

Use it when

  • The piping class allows threaded joints (utility air, water, low-hazard services)
  • Instrument connections must be removable
  • Hot work after installation must be avoided

Watch out for

  • B31.3 §314 restricts threaded joints where crevice corrosion, severe erosion or cyclic loading is expected; Chapter VIII limits them further in Category M service
  • Seal welding of threads only where the code and class permit
  • Check thread form (NPT vs BSPT) on imported items

4. Elbolet (outlet on an elbow)

On 90° elbowBW, SW or THD branchManufacturer design

Elbolet sectionOriginal schematic of an elbolet seated on the outside (extrados) of a long-radius 90 degree elbow, typically for a thermowell or instrument connection. Elbolet — outlet on a 90° elbow (extrados)Body contoured to theelbow’s compound curveBranch: BW, or SW/THDClass 3000 / 6000Order for LR or SR elbowand exact elbow size90° ELBOW (LR shown)Aienginear.com
Figure 5 — Elbolet seated on the outer curve (extrados) of a long-radius elbow, a typical thermowell position.

An elbolet has a base shaped to the compound curve of an elbow, so a branch can be taken off a bend. Its classic job is a thermowell or flow element on the elbow, with the sensor pointing straight into the oncoming flow. Most products suit 90° long-radius elbows; short-radius versions are made on request.

Use it when

  • Thermowells and probes need axial insertion into the flow
  • There is no room for a branch on the straight run

Watch out for

  • Order for the exact elbow: size, LR or SR, and wall
  • Elbows already carry higher stress — check with the stress engineer on hot or cyclic lines
  • Outside SP-97 scope: confirm the manufacturer’s design basis

5. Nipolet (outlet with integral nipple)

90°Plain (SW) or male-threaded endXS / XXS

Nipolet sectionOriginal schematic of a nipolet: a one-piece outlet with an integral extended nipple ending in a plain (socket-weld) or male-threaded end, used for vents, drains and valve take-offs. Nipolet — one-piece outlet with integral nippleRUN PIPE (HEADER) ℄FLOWoverall length(set by manufacturer)Male end: plain (SW) ormale-threaded (NPT)XS or XXS wall bodyIntegral nipple— no separate jointGroove weld to runAienginear.com
Figure 6 — Nipolet: outlet and nipple forged in one piece, ending in a plain end for a socket-weld valve or a male thread.

A nipolet combines an outlet and a pipe nipple in a single forging. Its free end is either plain (to fit into a socket-weld valve) or male-threaded (to screw into a threaded valve). Removing the separate nipple removes one joint and one potential leak path, which is why nipolets are popular for valved vents, drains and small take-offs. They are generally made in XS and XXS wall, in overall lengths of roughly 90 to 165 mm (3½ to 6½ in), depending on the manufacturer.

Common misconception: a nipolet is not simply a weldolet with a long neck, and it is not supplied with a butt-weld bevel or a female thread. It ends in a male (plain or threaded) connection.

Use it when

  • Valved vents and drains; small valve take-offs
  • Insulated lines where the valve must stand clear of the insulation

Watch out for

  • Long nipples on vibrating lines can fatigue — brace heavy valves
  • State the end type and overall length clearly on the requisition

6. Latrolet (45° lateral outlet)

45°BW, SW or THD branchMSS SP-97

Latrolet sectionOriginal schematic of a latrolet: a 45 degree lateral branch outlet welded to the run pipe, with the branch pointing in the direction of flow. Latrolet — 45° lateral branch outletRUN PIPE (HEADER) ℄FLOW45°BW, SW or THDbranch endElongated saddle basefollows the run contourFull-penetrationgroove weldAienginear.com
Figure 7 — Latrolet: an angled outlet for a 45° lateral branch, normally pointing with the flow.

A latrolet is used where the branch must leave the header at 45° instead of 90°. Typical reasons are a gentler flow split with less turbulence and pressure loss, a drain that should empty in one direction, or a clash with adjacent steel or piping. Its base is elongated along the pipe axis, so fit-up and the attachment weld are more demanding than for a 90° outlet. MSS SP-97 covers 45° outlets; other angles are special items made to order.

Use it when

  • Lateral branches, injection points and blowdown connections
  • Layout or flow direction makes 90° unsuitable

Watch out for

  • Mark the flow direction on the isometric so it is not installed backwards
  • The acute-side weld is hard to reach — plan the welding sequence

7. Coupolet (fire-protection outlet)

90°Female NPTListed for fire service

Coupolet sectionOriginal schematic of a coupolet: a light, female-threaded welded outlet used mainly in fire-protection sprinkler and other low-pressure piping. Coupolet — female NPT outlet for fire protection / low pressureRUN PIPE (HEADER) ℄FLOWFemale NPT thread(ASME B1.20.1)Light body, set-onwelded to headerCheck listing / rating(e.g. UL, FM)Aienginear.com
Figure 8 — Coupolet: a light, female-threaded welded outlet used mainly in sprinkler and low-pressure systems.

A coupolet looks like a thredolet but is a lighter fitting aimed at fire-sprinkler and other low-pressure piping. These products are typically UL listed and FM approved, with a working pressure around 300 psi (about 21 bar) in sprinkler service. They let sprinkler drops and branch lines screw directly into a welded main without a separate coupling.

Use it when

  • Fire-protection mains and branch lines designed to NFPA 13 or similar
  • Low-pressure water and air services the class allows

Watch out for

  • Not a substitute for a Class 3000 thredolet in process piping
  • Confirm the listing, size range and rated pressure from the product data sheet

8. Sweepolet (contoured, butt-welded outlet)

90°BW branch and BW attachmentManufacturer design

Sweepolet sectionOriginal schematic of a sweepolet: a contoured, integrally reinforced outlet whose saddle is butt-welded to the run pipe, giving a smooth flow path and low stress intensification. Sweepolet — contoured outlet, butt-welded to the headerRUN PIPE (HEADER) ℄FLOWButt weld at saddle edge— volumetric NDE possibleSmooth, swept transition(low SIF, good for fatigue)Butt weld to branchSaddle forms partof the run wallAienginear.com
Figure 9 — Sweepolet: the saddle is butt-welded into the header, and a smooth swept transition leads to the branch.

A sweepolet is a contoured outlet whose wide saddle is shaped to the run pipe and joined with a butt-type weld at its edge, so the fitting effectively becomes part of the header wall. The swept inside profile gives good flow, and the shape gives low stress intensification — valuable on headers with high pressure, thermal cycling or vibration. Because the attachment weld is a butt weld, it can be examined by radiography or ultrasonic testing, which is not practical on most set-on olets.

Use it when

  • High-pressure, high-temperature or fatigue-sensitive headers (steam, feedwater, high-pressure gas)
  • The class demands volumetric examination of branch welds

Watch out for

  • Larger hole and more cutting accuracy than a set-on olet
  • Higher cost and longer lead time; check size availability early
  • Not a pressure-vessel nozzle unless qualified under the vessel code

Other outlet variants worth knowing

  • Insert-type weldolet: partly inserted into the header opening and welded through the run wall; used on heavy-wall, high-pressure lines where a set-on profile is not acceptable.
  • Straight-bore (Flexolet-type) outlet: a butt-weld outlet with a straight, untapered bore; light-wall versions suit Sch 5S / 10S stainless piping.
  • Brazed outlet (Brazolet-type): for copper and copper-alloy tube systems joined by brazing.

Olet comparison table

AIENGINEARTable 4. Types of olets — quick comparison
TypeAngle / locationBranch endRating basisTypical useMain limitation
Weldolet90° on straight runButt-weld (bevel)Branch wall: STD, XS, Sch 160, XXSProcess branches NPS 2 and upAttachment weld hard to volumetric-test
Sockolet90° on straight runSocket-weldClass 3000 / 6000 / 9000Small-bore vents, drains, instrumentsCrevice; avoid in corrosive, erosive or severe cyclic service
Thredolet90° on straight runFemale NPTClass 3000 / 6000Instruments, plugs, utilitiesThreaded joints restricted by B31.3 §314
ElboletOn 90° elbow (extrados)BW, SW or NPTManufacturer designThermowells, probesMust match elbow size and radius
Nipolet90° on straight runMale: plain (SW) or threadedXS / XXS bodyValved vents and drainsVibration on long nipples
Latrolet45° lateralBW, SW or NPTAs 90° equivalentsLaterals, injection, blowdownHarder fit-up and welding
Coupolet90° on straight runFemale NPTListed rating, typically ~300 psiFire sprinkler, low pressureNot for process piping classes
Sweepolet90°, saddle in header wallButt-weldManufacturer designHP, HT, cyclic headersCost, lead time, cutting accuracy

Summary of MSS SP-97-2025 scope and typical manufacturer data. Compiled by Aienginear — aienginear.com/types-of-olets/

Olet selector and branch opening calculator

Enter the header and branch data. The tool picks the olet type, checks the MSS SP-97 wall pairing and the service limits for socket-weld and threaded ends, estimates the opening to cut in the header, and writes a ready-to-paste purchase description.

Aienginear · Olet Selector & Opening CalculatorPipe dimensions per ASME B36.10M / B36.19 · pairings per MSS SP-97-2025 · checks per ASME B31.3-2024
Recommended fitting—
Branch / run ratio—
Header OD × wall—
Estimated opening to cut—

    Purchase description

    —

    Screening tool only. The opening is estimated from the bore of the matching branch wall; cut to the manufacturer’s certified drawing and PFI ES-49. Branch-table limits vary by owner — your piping class governs.

    How to select the right olet

    Work through these checks in order. They mirror how a piping class and requisition are actually built.

    1. Read the branch table in the piping class. It decides tee, olet or stub-in for each size pair. Do not override it on site.
    2. Fix the governing code and fluid service — B31.3 Normal, Category D, Category M, High Pressure or severe cyclic; B31.1; or a fire code. The service decides whether SW or threaded ends are allowed at all.
    3. Record header and branch data: NPS, OD, schedule, material, corrosion allowance, design pressure and temperature.
    4. Choose the branch end: butt-weld for larger and critical branches; socket-weld or threaded only where the class permits; a male nipple end when connecting straight to a small valve.
    5. Choose the geometry: straight run (weldolet family), elbow (elbolet), 45° (latrolet) or low-stress contoured (sweepolet).
    6. Match the wall or class to the SP-97 pairings in Table 1; get manufacturer confirmation for mixed schedules.
    7. Match the material to the header: same P-number family, toughness for low temperature, PMI for alloys.
    8. Check layout and stress: weld access, clearance from other welds, valve weight, vibration and thermal movement.
    AIENGINEARTable 5. If you need… choose…
    RequirementUsual choiceCheck first
    Branch NPS 2 and up, hydrocarbon or steamWeldolet (tee if the branch is near full size)Branch table; wall pairing
    NPS ¾ vent or drain with a socket-weld valveNipolet (plain end) or sockolet + nippleSW allowed in the service
    Pressure gauge or transmitter tap, removableThredolet (where threads are allowed) or sockolet + threaded fittingB31.3 §314 and the class
    Thermowell facing the flowElbolet on a long-radius elbowElbow size, radius and wall
    Lateral injection or blowdownLatrolet (45°)Flow direction on the isometric
    Sprinkler branch on a welded mainCoupolet or another listed fire-protection outletUL / FM listing and rating
    High-pressure or fatigue-critical header, volumetric NDE requiredSweepolet or butt-welding teeDesign basis; lead time

    Typical selections; the project piping class governs. Compiled by Aienginear — aienginear.com/types-of-olets/

    Sizing and ordering an olet

    An olet is identified by header (run) size × branch size, plus the branch wall or class. Many manufacturers design one outlet to fit a range of header sizes (run-size consolidation), so the header size must still be stated to get the right base contour. A complete purchase description covers the items in Table 6.

    AIENGINEARTable 6. Olet purchase description checklist
    ItemWhat to stateExample
    Type and angle90°, 45° or elbow-mounted; set-on or insertBranch outlet, BW, 90°
    HeaderNPS and schedule; for elbolets, elbow size and LR/SRNPS 8 STD
    BranchNPS and wall (STD/XS/160/XXS) or class (3000/6000/9000)NPS 2 STD
    Branch endBW bevel to ASME B16.25, SW, NPT, or male plain/threaded (nipolet)Bevel to B16.25
    MaterialASTM grade and classASTM A105N
    StandardMSS SP-97-2025 or manufacturer design basisMSS SP-97-2025
    DocumentsMarking, certificate type, certified drawingEN 10204 3.1
    SupplementaryImpact testing, PMI, hardness, sour service (NACE MR0175 / ISO 15156)As per class

    Compiled by Aienginear — aienginear.com/types-of-olets/

    Example line item: Branch outlet, butt-weld, 90°, header NPS 8 STD × branch NPS 2 STD, ASTM A105N, MSS SP-97-2025, branch bevel to ASME B16.25, EN 10204 3.1 certificate. The calculator above writes this line for you.

    Installation, welding and inspection

    Olet installation sequenceOriginal step-by-step schematic for installing a set-on olet: mark and cut the opening, fit up with a root gap, weld with a full-penetration groove weld and cover fillet, then examine. Set-on olet installation — four steps1 Mark & cutHole = olet bore, not branch OD;grind smooth, remove slagcut = bore2 Fit-upCentre on hole; root gap per WPS(spacer wires); tack in 3–4 spotsroot gap (per WPS)3 WeldFull-penetration groove weld,then cover fillet; follow WPS/PQR4 Examine & testVT + MT/PT or as specified;include in leak test (B31.3 §345)examine weld (VT + MT/PT)Aienginear.com
    Figure 10 — Installation sequence for a set-on olet, following the approach in PFI ES-49 and ASME B31.3.
    1. Locate and mark. Keep the olet clear of other welds and supports as the class requires; check orientation against the isometric.
    2. Cut the hole to the outlet bore. The opening should match the bore at the base of the fitting, not the branch pipe OD. Grind smooth and remove slag. Never leave the run uncut — “blind” olets have been found in service.
    3. Fit up with a root gap as the welding procedure requires, centred on the hole. Tack in three or four places; spacer wires are a common method.
    4. Weld with a full-penetration groove weld plus cover fillet, using a qualified WPS and welder (ASME Section IX). Apply preheat and PWHT per B31.3 §330–331 based on the governing thickness of the joint.
    5. Control distortion on stainless and thin-wall headers with a balanced welding sequence and controlled heat input.
    6. Examine — visual examination as a minimum, plus MT or PT and any other method the fluid service and project specification require (B31.3 §341).
    7. Leak test the branch with the system (B31.3 §345), then file heat numbers, weld map, NDE and PWHT reports in the turnover dossier.
    AIENGINEARTable 7. Olet installation inspection checklist (hold points)
    StageCheckAccept whenRecord
    ReceiptMarking, material, size, class, certificateMatches requisition and MTC heat numberMaterial receipt report
    LayoutLocation, orientation, clearance to other weldsMatches isometric and class spacing rulesFit-up report
    OpeningHole diameter and finishEquals outlet bore per certified drawing; smooth, no slagFit-up report
    Fit-upCentring, root gap, tacks, preheatPer WPS; base seated on run contourFit-up / preheat log
    WeldingQualified welder, WPS, interpass temperatureFull-penetration groove + cover fillet profile per PFI ES-49Weld log, weld map
    PWHTCycle, thermocouples, hardnessPer B31.3 §331 and the classPWHT chart, hardness report
    NDEVT, MT/PT, RT/UT where possiblePer B31.3 §341 and fluid serviceNDE reports
    TestingLeak test with the systemNo leaks at test pressure, held per §345Test certificate

    Based on ASME B31.3-2024 and PFI ES-49-2023 practice. Adapt to your project ITP. Compiled by Aienginear — aienginear.com/types-of-olets/

    Common mistakes to avoid

    • Ordering by branch size only and forgetting the header size — the base contour will not fit.
    • Using a Class 3000 sockolet where the header needs Class 6000, or any mixed schedule without the manufacturer’s confirmation.
    • Cutting the hole to the branch OD (too big) or not cutting it fully (flow restriction, trapped debris).
    • Attaching the olet with a fillet weld only — the reinforcement is not achieved.
    • Using socket-weld or threaded outlets in services the class prohibits, such as Category M, severe cyclic or crevice-corrosive services.
    • Putting a coupolet in a process line because it “looks like a thredolet”.
    • Installing a latrolet against the flow direction.
    • Mounting an olet on a vessel without designing the opening to the vessel code.
    • Copying dimensions from a catalogue picture instead of the supplier’s certified drawing.

    Where olets are used

    Olets appear wherever headers feed smaller lines: oil and gas production and refining, petrochemical and fertilizer plants, power stations (steam, feedwater and drains), cement and steel plants (compressed air, cooling water, fuel oil), pharmaceutical and food plants (stainless utilities), and fire-protection systems. In maintenance and modification work they are especially valuable, because a new branch can be added to an existing header with a single cut and one attachment weld instead of removing a spool for a tee. Our types of pipe fittings guide shows where olets sit among elbows, tees, reducers and couplings.

    Key takeaways

    • An olet is an integrally reinforced branch fitting; the reinforcement only works with the correct wall pairing and a full-penetration attachment weld.
    • The types of olets differ by branch end (BW, SW, NPT, male nipple) and by geometry (straight run, elbow, 45°, contoured).
    • MSS SP-97-2025 is the current product standard; ASME B31.3-2024 and B31.1-2026 govern how olets are used.
    • Socket-weld and threaded outlets are for small bore and permitted services only.
    • Cut the hole to the outlet bore, weld to a qualified procedure, examine and test — and follow the piping class branch table.

    Glossary of olet terms

    • Run pipe / header: the larger pipe the branch leaves.
    • Set-on outlet: an olet that sits on the outside of the run pipe over a cut opening.
    • Integral reinforcement: extra metal forged into the fitting that replaces the metal removed by the opening.
    • Bore: the inside diameter of the outlet at its base; the header hole is cut to this size.
    • Branch connection table: the matrix in a piping class that fixes tee, olet or stub-in for each size pair.
    • SIF (stress intensification factor): the multiplier used in flexibility analysis for local stress at a fitting; ASME B31J now provides these values for B31.3.
    • Listed component: a fitting made to a standard named in the piping code, such as MSS SP-97.

    Frequently asked questions about olets

    What are the main types of olets?

    The main types of olets are the weldolet (butt-weld branch), sockolet (socket-weld branch), thredolet (female threaded branch), elbolet (fitted on an elbow), nipolet (integral nipple with a male end), latrolet (45° lateral), coupolet (light threaded outlet for fire protection) and sweepolet (contoured outlet butt-welded into the header).

    What is the difference between a weldolet and a sockolet?

    A weldolet has a bevelled end for a butt weld to the branch pipe and is used for larger and critical branches. A sockolet has a socket that receives the branch pipe, which is then fillet welded; it is used for small-bore branches, usually NPS 2 and below, where the piping class allows socket welds.

    What is the difference between a thredolet and a coupolet?

    Both have a female NPT thread. A thredolet is a Class 3000 or 6000 forged fitting for process and utility piping. A coupolet is a lighter fitting listed for fire-protection and other low-pressure systems, typically rated around 300 psi. They are not interchangeable.

    Which standard covers olets?

    MSS SP-97 is the product standard for 90° and 45° integrally reinforced forged branch outlet fittings with butt-weld, socket-weld and threaded ends; the current edition is SP-97-2025, published in March 2025. Their use is governed by the piping code, usually ASME B31.3-2024 for process piping or ASME B31.1-2026 for power piping.

    Does an olet need a reinforcement calculation?

    Not if it is an MSS SP-97 fitting used within its scope, with the correct header and branch wall pairing and a full-penetration attachment weld; ASME B31.3 §304.3.2 accepts listed branch fittings. Special outlets made to a manufacturer’s design, or mixed-schedule combinations, need their design basis confirmed.

    What size hole should be cut for an olet?

    The hole should match the bore of the olet at its base, as shown on the manufacturer’s certified drawing and recommended in PFI ES-49. It should not be cut to the branch pipe OD, and the run must never be left uncut.

    When should a tee be used instead of an olet?

    Use a tee when the branch is the same size as, or close to, the run size; when the piping class branch table requires it; or when all welds must be volumetrically examined. Olets suit branches that are clearly smaller than the run.

    What is a nipolet used for?

    A nipolet is a one-piece outlet with an integral nipple, ending in a plain end for a socket-weld valve or a male thread for a threaded valve. It is used mainly for valved vents, drains and small take-offs, and it saves one joint compared with an outlet plus a separate nipple.

    Why use a sweepolet?

    A sweepolet has a contoured saddle that is butt-welded into the header and a smooth swept bore. It gives low stress intensification and allows radiographic or ultrasonic examination of the attachment weld, so it suits high-pressure, high-temperature and fatigue-sensitive headers.

    Can olets be used on pressure vessels?

    Yes, but the opening must then be designed to the vessel code, such as ASME BPVC Section VIII Division 1, not to the piping code. Confirm that the fitting, material and weld details are accepted by the vessel designer and inspector.

    Can socket-weld or threaded olets be used in any service?

    No. ASME B31.3 advises against socket welds and threaded joints where crevice corrosion, severe erosion or cyclic loading may occur, and restricts them further in Category M service. The project piping class is the final authority.

    Which header and branch wall combinations does MSS SP-97 cover?

    Unless the manufacturer states otherwise, conventional SP-97 outlets are intended for STD × STD, XS × XS, Sch 160 × Sch 160, XXS × XXS, XS × Class 3000, Sch 160 × Class 6000 and XXS × Class 9000. Mixed schedules must be confirmed with the manufacturer.

    Test your knowledge: types of olets quiz

    Aienginear Olets Quiz · 8 questions · Score: 0 / 8

    1. Which olet has a bevelled branch end for a butt weld?

    A weldolet’s branch end is bevelled to ASME B16.25 for a butt weld.

    2. What is the current edition of MSS SP-97?

    MSS SP-97-2025 was published in March 2025 and replaced the 2019 edition.

    3. The opening in the header for a set-on olet should be cut to…

    Cut the hole to the outlet bore per the certified drawing and PFI ES-49.

    4. Which SP-97 pairing is standard for a Class 6000 socket-weld outlet?

    Sch 160 × Class 6000 is one of the conventional SP-97 combinations.

    5. Which olet fits on the outside curve of an elbow?

    An elbolet is contoured to the elbow’s compound curve, often for thermowells.

    6. Which olet allows radiography of the attachment weld?

    A sweepolet is butt-welded into the header, so the attachment weld can be RT or UT examined.

    7. A coupolet is mainly used in…

    Coupolets are light, listed outlets for sprinkler and low-pressure systems.

    8. How must an olet be attached to the run pipe under ASME B31.3?

    B31.3 §328.5.4 requires fully penetrated groove welds for branch fittings that abut the run.

    References

    • MSS SP-97-2025, Integrally Reinforced Forged Branch Outlet Fittings — Socket Welding, Threaded, and Buttwelding Ends.
    • ASME B31.3-2024, Process Piping.
    • ASME B31.1-2026, Power Piping.
    • ASME BPVC Section VIII, Division 1 (2025), Rules for Construction of Pressure Vessels.
    • ASME B16.11-2021, Forged Fittings, Socket-Welding and Threaded; ASME B16.25, Buttwelding Ends; ASME B1.20.1, Pipe Threads, General Purpose (Inch); ASME B36.10M and B36.19, pipe dimensions.
    • PFI ES-49-2023, Guidelines for Installation of Integrally Reinforced Branch Connection Fittings.
    • Manufacturers’ branch connection catalogues and certified drawings for the specific product purchased.

    Disclaimer: This guide is for education and early-stage planning. Design, procurement and construction must follow the contract edition of the governing code, the project piping class, approved drawings and the manufacturer’s certified data. Figures are original Aienginear schematics and are not to scale.

    Written and reviewed by Muhammad Raza — 18+ years in mechanical installation, piping and plant projects across power, cement, fertilizer and oil & gas. Publisher of Aienginear.com: engineering calculators, technical articles and standards & design tools.
    Last updated: 23 November 2026
    Aienginear

    Written by Muhammad Raza

    Founder of Aienginear, with 18+ years managing piping, mechanical installation, plant shutdowns and turnarounds in power, cement, fertilizer and oil & gas plants.

    LinkedIn · YouTube · Report an error or ask a question

    Leave a Comment